BS-230 Auto Clinical Chemistry Analyzer
Discrete, random access, fully automated, bench-top Up to 200 tests per hour, up to 400 tests per hour with ISE Optical system: 8 wavelengths 100µl minimum reaction volume Independent mixing bar Up to 80 positions for reagent, Up to 80 positions for sample 2~12℃ cooling compartment for reagent and sample 40 disposable reaction cuvettes Sample volume: 2μL~45μL, step by 0.1μL, reagent volume: 10μ L~250μL, step by 0.5μL Automatic probe cleaning for interior and exterior Liquid level detection and collision protection for probes Bi-directional connection to LIS host Original system pack reagent ready to use
System function:
Automatic, Discrete, Random Access, Bench-top
STAT sample priority
Throughput
Up to 200 tests/hour, up to 400 tests/hour with ISE
Measuring principles:
Absorbance photometry, Turbidimetry, Ion
Selective Electrode technology
Methodology:
End-point, Fixed-time, Kinetic, optional ISE,
Single/Dual/ reagent chemistries,
monochromatic / bi-chromatic
Original system pack reagent ready to use
Close system and open system is optional
Reagent/Sample Handling
Reagent/Sample tray:
80 positions for reagents and 40 positions
for samples in the 24-hour refrigerated
compartment (2~12℃)
Reagent volume:
10~250μl, step by 0.5μl
Sample volume:
2~45μl, step by 0.1μl
Reagent/Sample probe: Liquid level detection, vertical collision
protection and inventory checking, reagent pre-warming
Probe cleaning:
Automatic washing for interior and exterior
Carry over < 0.05%
Probe cleaning: Automatic washing for interior and exterior Carry over < 0.05%
Internal bar code reader (optional)
Capable to communicate with LIS in bi-directional mode
Reaction System:
Cuvette: 40 disposable cuvettes
Reaction volume: 100~360μl
Operating temperature: 37℃±0.1℃
ISE Module (optional)
Measuring K+, Na+, Cl-
Mixing Unit:
Independent mixing bar
Optical System
Light Source:
Halogen-tungsten lamp
Wavelength:
8 wavelengths, 340nm、405nm、450nm、
510nm、546nm、578nm、630nm、670nm
Absorption range:
0~4.0 Abs (10mm conversion), resolution 0.0001Abs
Stray Light:
5.6Abs
Control and Calibration
Calibration modes:
Linear (one point, two points and
multi-points), Logit-Log 4P, Logit-Log 5P,
spline, exponential, polynomial, parabola
Control Rules:
X-R, L-J, Westgard multi-rule, Cumulative sum
check, twin plot
Operation Unit
Operation system:
Windows 8
Interface:
RS-232
Working Conditions
Power Supply:
200~240V, 50/60Hz, ≤1000VA or 100~130V, 60Hz, ≤1000VA
Dimension:
690 mm (length) ×580 mm (depth) ×595 mm (height)
Weight:
47 kg
Water Consumption:
≤ 2 L/H