BC-760&780 Auto Hematology Analyzer
Accurate: Great correlation with the Westergren method Same QC and calibrator as in the BC-6000 series The combined examination helps to avoid the interferences of dehydration, polycythemia, vera, and anemia on ESR results; Cost-effective: The integrated instrument is capable of both CBC and ESR detection; Takes up the space of only one analyzer. Automatic: Report CBC + ESR results together within 1.5 min; The measurement results are protected against the influence of subjective factors; Automation can reduce the biosafety hazards that may otherwise be introduced by a manual method.
Principles:
WBC (IMG/Neu/Mon/Lym/Eos/Bas), NRBC/RET*, PLT-H/PLT-O*/IPF: SF Cube ^ Cell Analysis, Technology ^S: Scatter; F: Fluorescence; Cube: 3D analysis
RBC, PLT:
Focusing Flow-DC Impedance Method
HGB:
Colorimetric method
ESR:
Photometric method
(Number of measuring parameters (whole blood): 109, Number of reportable parameters: 41): WBC Bas# Bas% Neu# Neu% Eos# Eos% Lym# Lym% Mon# Mon% IMG# IMG% RET%* RET#* RHE* IRF* LFR* MFR* HFR* RBC HGB MCV MCH MCHC RDW-CV RDW-SD HCT NRBC# NRBC% PLT PLT-I PLT-H PLT-O* MPV PDW PCT P-LCR P-LCC IPF ESR
Number of research parameters:
68*
Number of measuring parameters (body fluid):
18
Number of reportable parameters:
7 -WBC-BF TC-BF# MN# MN% PMN# PMN% RBC-BF
Number of research parameters:
11
Sample volume:
CD (whole blood): 25ul, CD+ESR (whole blood): 160ul, Predilute: 20ul
Data storage capacity:
Up to 150,000 results including numeric and graphical information *
Throughput:
CD 80t/h CDR 45t/h CD+ESR 40t/h
Analysis Mode:
Whole blood (CBC, CBC + DIFF, CBC + DIFF + RET*, CD + ESR, CDR + ESR*, CD/WBC-3X, CDR/PLT-5X*, and other modes), Predilute (CBC, CBC + DIFF, CDR*, and other modes), Body fluid (CBC+DIFF): CBC + DIFF
Dimensions:
840D x 655W x 600H mm
Weight ≤70.6Kg
Voltage 100V-240V~ (±10%)
Frequency 50Hz/60Hz (±1Hz)
Power input 600VA
External output LANx1, USB x 4 (Specifications: DC 5V; 500mA; USB2.0 x 3; USB3.0 x 1)
Normal Operating Environment:
Ambient temperature: 10℃ ~ 35℃
Relative humidity: 30% ~ 85%
Atmospheric pressure:
70.0kPa ~ 106.0kPa^, ^
Note: Required altitude for normal operation: -400m ~ +3000m
Performance:
WBC: 0-500×109 /L, ≤2.5% (≥4.51×109 /L), ≤ 1.0%
RBC: 0-8.60×1012/L, ≤1.5% (≥3.5×1012/L), ≤ 1.0%
HGB: 0-260g/L, ≤1.0% (110-180g/L), ≤ 1.0%
HCT: 0-75%, ≤1.5% (30%-50%), ≤ 1.0%
PLT*: (0-5000×109 /L, ≤ 1.5(SD) (≤20×109 /L)^, ≤ 2.5% (≥100×109 /L)^), ≤ 1.0%
RET*: 0-0.8×1012/L, ≤15% (RBC ≥ 3.00×1012/L RET%: 1.00% ~ 4.00%), ≤ 1.0%
ESR: ≤1.8(SD)(0~20mm/h), ≤ 1.0%